Mecanical BIM services

We can model the Mechanical (HVAC) Ducting/ Piping BIM services based on the input CAD, PDF and from the design IFC files as per specifications and standards required. The HVAC BIM Services are coordinated with the Architecture and Structure models to eliminate interference. The interference rectification will be done in coordination with the client and considering the design requirements.

  • Ducting & Piping shop drawings
  • Ducting & Piping Modeling
  • Chilled Water Schematics
  • Detail Installation Drawings
  • Combine Builders Work
  • Mechanical plant rooms
  • 2D Documentation works
  • Scheduling (BOQ)
  • 4D Construction Phasing & Monitoring
  • Equipment Pad Layouts
  • Rendered views of Mechanical BIM Models

HVAC

Heating, ventilation, and air conditioning (HVAC) is the technology of indoor and vehicular environmental comfort. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a sub discipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation, as HVAC&R or HVACR or "ventilation" is dropped, as in HACR.

Ducting modelling

Ducts are conduits or passages used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. The needed airflows include, for example, supply air, return air, and exhaust air. Ducts commonly also deliver ventilation air as part of the supply air. We model BIM services based on the input CAD, PDF and from the IFC design files as per specifications and standards required.

Challed water modelling

Chilled water is a commodity often used to cool a building's air and equipment, especially in situations where many individual rooms must be controlled separately, such as a hotel. The chilled water can be supplied by a vendor, such as a public utility or created at the location of the building that will use it, which has been the normal to eliminate interference.We can model the Chilled Water BIM services based on the input CAD, PDF and from the Design IFC files as per specifications and standards required. The HVAC BIM Services are coordinated with the Architecture and Structure models to eliminate interference. The interference rectification will be done in coordination with the client and considering the design requirements.

Plant room

A mechanical room or a boiler room is a room or space in a building dedicated to the mechanical equipment and its associated electrical equipment as opposed to rooms intended for human occupancy or storage. Unless a building is served by a centralized heating plant the size of the mechanical room is usually proportional to the size of the building. A small building or home may have at most a utility room but in large buildings mechanical rooms can be of considerable size often requiring multiple rooms throughout the building or even occupying one or more complete floors.

MEP fabrication

A step on from installation drawings are fabrication drawings. We have often produced fabrication drawings from our coordinated ductwork model. When doing these drawings we liaise with the ductwork fabricator to ascertain their standard manufacturing dimensions such as cut-length and gasket thickness Fabrication detailing in Revit supports different MEP detailing workflows.You can then place parts to create a detailed fabrication model in Revit. You can also convert an existing Revit model with generic duct, pipe, and electrical containment parts to a model that uses fabrication parts.